| Model | 12kW (single-phase) fast-charging station |
|---|---|
| Input Parameters | |
| Rated Input Voltage | Single-phase 220Vac (two inputs) |
| Input Voltage Range | 187Vac–264Vac (full load); 85Vac–187Vac (linear derating) |
| Rated Input Current | < 40A |
| Input Frequency | 45Hz–65Hz |
| Power Factor (PF) | ≥0.99 (full load) |
| Total Harmonic Current Distortion (THD) | ≤ 5% |
| Input Protection | Built-in fuse, lightning protection, over/under-voltage, surge suppression |
| Output Parameters | |
| Rated Output Power | 12kW |
| Rated Output Current | 200A (single channel) |
| Output Current Adjustment Range | 0A–200A (continuously adjustable) |
| Output Voltage Range | 16Vdc–120Vdc |
| Voltage Regulation Accuracy | ≤±1% (full load / half load) |
| Current Regulation Accuracy | ≤±1% (full voltage range) |
| Module Current Sharing Error | ≤±5% (multiple modules in parallel) |
| Overall Efficiency | ≥94% (rated full load) |
| Output Interface | Customized two-wheeler DC fast charging interface (optional national standard / industry common interface) |
| Operating Environment | |
| Operating Ambient Temperature | -40℃~60℃ (full load); 60℃~75℃ (derating) |
| Storage Temperature | -40℃~75℃ |
| Relative Humidity | 0~95% RH (non-condensing) |
| Operating Altitude | ≤2000m (full load); >2000m derating |
| Protection Level | IP54 (outdoor column type, dust-proof and rain-proof) |